Description

When running the NP02 coldbox (first minute of run 40915), there was a run taken with the RTCM with a rate of 0.01Hz, but no TCs were generated. This was only fixed when the rate was changed to 0.1Hz. The changes to the base 5.4.3 vd-coldbox configuration included (and are verifiable from the run registry):

  • tBefore = 0.5ms
  • tAfter = 2ms
  • mlt post processing ticks = 0
  • tpg disabled

Steps to reproduce

Setup a 5.4.3 area
Create a run using the NP02 CB with the above instructions.
Observe no TCs being generated with a rate of 0.01 Hz.

Version and environment

fddaq-v5.4.3

Impact

Small/Isolated