Skip to content

[BUG] MOV (A0-A3) imm len problem #5

@MeiVinEight

Description

@MeiVinEight

image
This picture is from Intel® 64 and IA-32 Architectures Volume 2.
MOV (A0-A3) opcode's is always 64-bit in 64-bit mod, this conclusion comes from HxD:
image
When it disassembles this machine code, the imm len is 8 bytes,