Notifications
You must be signed in to change notification settings - Fork 56
Description
I have an .ssp with a SystemStructure.ssd file that has an .fmu with unit = "" on all outputs in its ModelDescription file. When I add unit to one of these connectors in SystemStructure.ssd:
<ssd:Connector name="pLin.in.y" kind="output" description="">
<ssc:Real unit="bar"/>
</ssd:Connector>
and connect this connector to another connector in the .ssd with the same unit:
<ssd:Connector name="pLin" kind="input" description="Input load pressure">
<ssc:Real unit="bar"/>
</ssd:Connector>
<ssd:Connection endConnector="pLin" endElement="valve_model" startConnector="pLin.in.y" startElement="interface_model"/>
I get error:
error: [addConnection] Unit mismatch in connection: interface_model.pLin.in.y -> valve_model.pLin
error: [importFromSnapshot] Failed to import ssd:Connection
If I instead have
<ssd:Connector name="pLin.in.y" kind="output" description="">
<ssc:Real unit=""/>
</ssd:Connector>
I get no error.
Should not the units in the ssd override the units in the FMU?
Also, the fmu for valve_model has units on all connectors.
My ssp as zip:
ParkerSimPack.zip
Running OMiImulator python api, version 'OMSimulator v2.1.3-win-notlm'